ECG-6BW ECG machine.( 6 Channel )

Item No.: ECG-6BW
Min. Order: 1 Piece

Feature :  

The unit able to sample 12-lead ECG at the same time, by placing 10 -electrode on patient.

The unit able to display 12-lead ECG waveform on the screen at the same time.

The unit able to input patient information with the alphanumeric / touch screen keyboard

The unit able to generate an ECG report in 110mm size paper by built-in thermal recorder.

The unit able to generate measurements and diagnosis information on the report. 

 

Display:

The unit should be configured with 7 inch color touch LED/LCD or TFT screen to view all 12/6-lead ECG waveform.

The screen should display information including: Patient name, Patient ID, Patient Gender, Patient Age, real-time Heart Rate, Time, battery status, technical error hint, lead-off hint, 12/6-lead ECG waveform with lead tags.

● The screen should be able to show the lead placement in an intuitive way, and the lead-off and lead-interference could hint in different color on the lead placement figure.

Input:

● The unit should support patient information inputting through the built-in Qwerty / touch screen keyboard.

● The unit should have one-button operation to realize sampling, analyzing, printing, saving and transmitting ECG report in one press.

● The unit should have short-cut key to change the information of patient gender and patient age range so the ECG practice could be faster.

● The unit should have short-cut key to enable and disable the thermal printer so user could be more flexible in generating the report.

● The unit should have short-cut key to craze the patient personal information so the user could be more efficient in inputting patient information.

Operation & Functions :

● The unit should support auto/manual work mode.

● The unit should be able to have minimum 3 minutes ECG sampling and recording to evaluate the Heart Rate

 Variability and generate a report with R-R histogram.

● The unit should be able to generate a rhythm lead ECG report with one rhythm lead recording for one minute and

 printing. And the rhythm lead ECG should be saved also in the internal memory.

● The unit should have the periodic sampling function in a period of time with user-defined sampling intervals.

● The unit should be able to sample ECG patient for a period of time, and only automatically print ECG when the unit

 sense the arrhythmia happening

The unit should be able to clear all patient personal information automatically after all the electrodes are

 taken offer

The unit should be able to give hint on empty patient ID before sampling.

The patient ID can be set as generated by time, by manually input.

The patient information could be filled by selecting patient from work list.

The unit should support waveform freezing and review, and ECG report could be analyze an printed from

  the review page.

Unit can support preview before printing. 

The unit should be able to set the following information, choosing to print or not to print on the report:

  Measure /Analysis /Diagnosis Conclusion/ Report Confirm /Template /Position Marker /Time Scale.

The unit should be able to change the gain in the sampling interface, the value could be set as 2.5mm/mV,

  5mm/mV, 10mm/mV, 20mm/mV, 10/5mm/Mv.

The unit should be able to change the paper speed in the sampling interface, the value could be set as

  5mm/s / 6.25mm/s10mm/s / 12.5mm/s25mm/s50mm/s.

Technical Specification: 

Sampling Rate should be at least 16000/32000 samples /sec/lead

Frequency Range should be 0.-1Hz-150Hz or more

Baseline filter should include 0.01 Hz, 0.05Hz, 0.32Hz, and 0.67Hz, ECG filter should include 25Hz,

 35Hz and 45Hz; Low pass filter should include 75Hz, 100Hz, 150Hz, or more AC filter should be able to

 switch on/off

AD converter should be at least 16/24 bit.

The common mode rejection ratio should be at least 140dB (AC on) and 123dB (AC off).

The unit should be able to store at least 200ECG report by the internal memory, and it should support extending storage by USB flash disk.

The unit should be able to lock the USB or other external storage function with a system password to unlock so that data can be safe.

The built-in battery should have minimum 3 hours battery backup & should be able to print at least ECG record when it is fully charged. To fully charge the battery should take no more than 3.5 hours

Interpretation & Application

● The unit should support Qte formulas including Bazett. Framingham, Fridericia and Hodge.

Connection

● The unit will be able to generate ECG report in the format of DICOM, SCP, FDA, XML/PDF/ JPEG.

● The unit will be able to connect ECG data management software package system to receive patient information and uploading ECG report.

● The unit will be able to synchronize system time with the connection of data management system

Accessories :

1.      Patient Cable .                      1 set

2.      Limb electrode ( clip type )  1set

3.      Chest electrode                     1set

4.      Power cord                            1pc

5.         Dusts cover                           1pc

6.      Recording paper                   10rolls/Pieces

7.      ECG Gel                                5 liter (with 2 dispenser)